LIQUID PIPE FLOW: FLOW RATE CALCULATION

SI/Metric Units


INPUT   DATA

Title  

Available Pressure head, h   m  
Fluid specific gravity, γ    
Kinematic viscosity, ν   cSt  
Pipe diameter, D   mm  
Pipe roughness, ε   mm  
Pipe length, L   m  
Fittings/minor losses, Lm   m  
Elevation change, ΔZ   m  


       Reset


RESULTS

VARIABLES   Values   Units
 ♦ Flow velocity, V   1.604 m/s 
 ♦ Reynolds number, Re   621286.3  
 ♦ Flow regime   Turbulent  
 ♦ Darcy Friction factor, ƒd   0.01444  
 ♦♦ Flow rate, Q   680.44 m3/hr 
 ♦♦  Pressure head, ΔP   14607.84 N/m2 
 ♦ Minimum Pumping Power   2.76 kW